Product features: Use 0.1 micron MPPS testing instrument for performance testing, product quality is guaranteed; produced in a class 10,000 clean factory, no volatile dust; using high-quality HV filter material, stable efficiency, low resistance, long service life; small size, saving installation space; high strength, light weight, easy to install.
Performance parameters: Full efficiency test (0.1-0.2μm): 99.9995%; Most penetrating particle size scanning method (MPPS), filtration level: U15;
Filter material: glass fiber filter paper
Frame: frosted aluminum profile
Dividers: hot melt glue
Working temperature: -20~70℃
Working humidity: ≤99%

| Model specifications | Dimensions (A*B*C) | Rated air volume | Initial resistance | ||
| H13 | H14 | H15 | |||
| BY-WG 570*570*69 | 570*570*69 | 500 | 100 | 120 | 200 |
| BY-WG 1170*570*69 | 1170*570 *69 | 1000 | 100 | 120 | 200 |
| BY-WG 1170*870*69 | 1170*870*69 | 1500 | 1 00 | 120 | 200 |
| BY-WG1170*1170*69 | 1170*1170*69 | 2000 | 100 | 120 | 200 |
| BY-WG 1495*1295*69 | 1495*1295*69 | 3100 | 100 | 120 | 200 |
| BY-WG 610,610*69 | 610*610*69 | 1000 | 190 | 210 | 240 |
| BY-WG1 220*610*69 | 1220*610*69 | 2000 | 190 | 210 | 240 |
| BY-WG 320*320*80 | 320*320*80 | 300 | 160 | 180 | 210 |
| BY-WG 484*484*80 | 484*484*80 | 600 | 160 | 180 | 210 |
| BY-WG 630*630*80 | 630*630*80 | 1100 | 160 | 180 | 210 |
| BY-WG 305*610*80 | 305*610*80 | 500 | 160 | 180 | 210 |
| BY-WG 610*610*80 | 610*610*80 | 1000 | 160 | 180 | 210 |
| BY-WG 915*610*80 | 915*610*80 | 1500 | 160 | 180 | 210 |
| BY-WG 1220*610*80 | 1220*610*80 | 2000 | 160 | 180 | 210 |
| BY-WG 320*320*93 | 320*320*93 | 300 | 150 | 160 | 200 |
| BY-WG 484*484*93 | 484*484*93 | 600 | 150 | 160 | 200 |
| BY-WG 630*630*93 | 630*630*93 | 1100 | 150 | 160 | 200 |
| BY-WG 610*610*93 | 610*610*93 | 1000 | 150 | 160 | 200 |
| BY-WG 915*610*93 | 915*610*93 | 1500 | 150 | 160 | 200 |
| BY-WG 1220*610*93 | 1220*610*93 | 2000 | 150 | 160 | 200 |
| BY-WG 400*400*93 | 400*400*93 | 500 | 190 | 220 | 270 |
| BY-WG 550*550*93 | 550*550*93 | 1000 | 190 | 220 | 270 |
| BY-WG 660*660*93 | 660*660*93 | 1500 | 190 | 220 | 270 |
| BY-WG 320*320*95 | 320*320*95 | 300 | 150 | 160 | 200 |
| BY-WG 484*484*95 | 484*484*95 | 600 | 150 | 160 | 200 |
| BY-WG 630*630*95 | 630*630*95 | 1100 | 150 | 160 | 200 |
| BY-WG 610*610*95 | 610*610*95 | 1000 | 150 | 160 | 200 |
| BY-WG 915*610*95 | 915*610*95 | 1500 | 150 | 160 | 200 |
| BY-WG1 220*610*95 | 1220*610*95 | 2000 | 150 | 160 | 200 |
| BY-WG 400*400*95 | 400*400*95 | 500 | 190 | 220 | 270 |
| BY-WG 550*550*95 | 550*550*95 | 1000 | 190 | 220 | 270 |
| BY-WG 660*660*95 | 660*660*95 | 1500 | 190 | 220 | 270 |
The mini-pleat structure optimizes airflow paths, reducing system pressure loss and energy consumption.
Provides a larger filtration area within the same dimensions, increasing dust-holding capacity and service life.
The design eliminates metal separators, reducing overall weight and simplifying installation.
Achieves H13/H14 filtration performance to meet stringent air cleanliness requirements.
Well suited to modern energy-efficient HVAC and variable air volume (VAV) systems.
Hot-melt adhesive spacers support the filter media, maintaining its shape during long-term operation.
Separator-free mini-pleat structure
Ultra-low operating resistance
High filtration efficiency: H13–H14
Efficient capture of 0.3 μm particles
Lightweight design
Large filtration area
Energy-efficient and environmentally friendly
OEM/ODM customization available
Used for specified terminal filtration stages in production, filling, and packaging areas. Confirm filter class, rated airflow, sealing, and installed leak-testing requirements according to project specifications.
Can be used in designated filtration stages serving operating rooms and clean wards. Verify ventilation requirements, installation dimensions, allowable pressure drop, and maintenance access.
Used in clean air systems for electronics assembly and semiconductor-related production. Specify particle control targets, operating airflow, filter class, and material cleanliness requirements.
Can be used for laboratory supply or exhaust filtration according to the design. Confirm housing sealing, leak-testing conditions, and safe replacement arrangements based on containment requirements.
Used for terminal particulate filtration in areas requiring controlled air cleanliness. Specify hygiene requirements, temperature, humidity, and cleaning conditions to confirm media and frame configurations.
Can be used in equipment or air treatment units where HEPA filtration is explicitly required. Verify particle control needs, available fan pressure, and airflow before replacing conventional filters.
The low-resistance design significantly reduces fan energy consumption.
A larger filtration area provides greater dust-holding capacity.
The separator-free design reduces weight and simplifies installation and maintenance.
Suitable for clean air systems operating continuously.
Available in various dimensions, efficiency classes, and frame materials.
Confirm H13 classification and the test standard according to project requirements. Verify model-specific efficiency data, test airflow, and individual filter test documentation.
For filtration locations where H14 is specified. Confirm pressure drop at actual airflow, fan capacity, sealing, and installed leak-testing requirements.
Suitable for equipment projects specifying plastic frames. Confirm operating temperature, structural strength, dimensional tolerances, and project flame-retardancy requirements.
Suitable for equipment with weight and installation requirements. Verify profile dimensions, frame strength, mounting methods, and sealing compatibility.
Available for compatible air handling units and filter housings. Confirm frame thickness, site corrosion conditions, installation dimensions, and mounting methods before ordering.
Double-sided gaskets can be configured according to housing requirements. Specify gasket material, position, thickness, and compression, and verify sealing surfaces and clamping arrangements.
Provide continuous temperature, peak temperature, and exposure duration. Confirm the temperature limits of the media, hot-melt adhesive, sealant, gaskets, and frame together.
Assess media area and pleat configuration according to design airflow and allowable pressure drop. Compare data at the same efficiency class, dimensions, and airflow.
Custom dimensions, labels, packaging, and branding are available. Provide technical drawings, testing requirements, quantity, and delivery schedules to confirm the production plan.
Focused on the development and manufacture of high-efficiency and ultra-high-efficiency air filtration products.
Each filter undergoes efficiency and leak testing.
Products are widely used in pharmaceutical, healthcare, electronics, and scientific research applications.
Standard models are well stocked, with bulk supply available for projects.
Supporting customized cooperation with global brands and engineering projects.
Mini-pleat filters offer lower resistance and lighter weight, making them well suited to modern energy-efficient HVAC systems. Separator-type filters are more suitable for high-airflow and demanding operating conditions.
Yes. They are widely used for terminal filtration in hospital operating rooms and clean healthcare systems.
They typically achieve H13 or H14 classification, corresponding to efficiencies of 99.95%–99.995%.
Yes. Filters can be manufactured according to project requirements.
Yes. Both OEM and ODM services are available.
Looking for mini-pleat HEPA filters for AHUs, FFUs, or cleanroom air conditioning systems?
Please provide the following information for selection and quotation:
Filter dimensions: External frame length × width × depth, installation opening, and mounting method. Attach existing filter photos or drawings for replacement projects.
Filter class: Required H13 or H14 classification, test standard, and individual test report requirements.
Airflow and pressure drop: Design airflow per filter, allowable initial pressure drop, specified final pressure drop, and available fan static pressure.
Sealing requirements: Specify gasket or gel-seal requirements, installation interfaces, and leak-testing requirements. The construction should be confirmed according to the equipment.
Operating conditions: Application area, operating hours, temperature, humidity, condensation conditions, and special cleaning requirements.
Purchase quantity: Current quantity, sample requirements, future replacement plans, packaging, and delivery schedule.
Our engineers will provide selection recommendations and a quotation within 12 hours.
Looking for a reliable manufacturer of air filtration, air distribution, and cleanroom equipment? We provide high-quality products, competitive factory pricing, and flexible OEM/ODM customization services for global customers, meeting the diverse needs of industrial, medical, cleanroom, and HVAC projects.
We can arrange third-party inspection and issue this attestation for each shipment, supporting customs clearance and L/C presentation.
Address: No. 458 Jiangping Road, Jingjiang City, Jiangsu Province, China
Payment Terms: L/C, T/T, D/P
International Trade Terms: FOB, CFR, CIF, DAP, EXW
Average Lead Time: Peak season: one month; off season: within 15 working days
Nearest Port: Shanghai
Looking for a reliable supplier of air filtration, air distribution, or cleanroom system products? We provide factory-direct pricing, customized OEM/ODM services, and complete engineering project solution support.
Submit your requirements, and our engineering team will provide a dedicated solution and quotation within 12 hours, including detailed product specifications and delivery lead time.